Wide-energy neutron dose monitor


Product Overview

RP4005-WE wide energy neutron dose monitor is a wide energy neutron detector. It adopts a large volume 3He proportional counter tube. The overall design has been excellently improved. It has ultra-high sensitivity and gamma suppression. It has a more accurate response to high energy neutron fields and can reflect the neutron dose level of the surrounding environment in real time. It has multi-channel alarm signal output and can be connected to the radiation field safety interlock control system.

Product Overview

RP4005-WE wide energy neutron dose monitor is a wide energy neutron detector. It adopts a large volume 3He proportional counter tube. The overall design has been excellently improved. It has ultra-high sensitivity and gamma suppression. It has a more accurate response to high energy neutron fields and can reflect the neutron dose level of the surrounding environment in real time. It has multi-channel alarm signal output and can be connected to the radiation field safety interlock control system.

Features

① He-3 proportional counter tube, high sensitivity, precise measurement;

② Wide energy response, meeting the requirements of high-energy neutron specific locations;

③ Portable for mobile inspection, and can also be used as fixed-point dose monitoring;

④ Multi-level alarm threshold, continuously settable within the full range;

⑤ Multi-channel alarm output signal, can be connected to the safety interlock system.

Features

① He-3 proportional counter tube, high sensitivity, precise measurement;

② Wide energy response, meeting the requirements of high-energy neutron specific locations;

③ Portable for mobile inspection, and can also be used as fixed-point dose monitoring;

④ Multi-level alarm threshold, continuously settable within the full range;

⑤ Multi-channel alarm output signal, can be connected to the safety interlock system.

Technical Parameters

Product Model

RP4005-WE

Detector Type

3He proportional counter tube

Measuring range

100nSv/h~100mSv/h

Relative intrinsic error

±20%

Energy range

0.025eV (hot) ~ 5GeV

Sensitivity

≥0.84cps/μSv/h(252Cf)

Angular response (2π)

±20%

Gamma inhibition

0~5μSv/h (100mSv/h,662keV)

Technical Parameters

Product Model

RP4005-WE

Detector Type

3He proportional counter tube

Measuring range

100nSv/h~100mSv/h

Relative intrinsic error

±20%

Energy range

0.025eV (hot) ~ 5GeV

Sensitivity

≥0.84cps/μSv/h(252Cf)

Angular response (2π)

±20%

Gamma inhibition

0~5μSv/h (100mSv/h,662keV)