Column-type pedestrian radioactivity monitoring system


Product Overview

The CRMS2000-C column-type pedestrian radioactivity monitoring system is equipped with a high-sensitivity γ radiation detector and a neutron detector (optional) for automatic radioactivity monitoring. It can quickly, effectively and non-destructively check the radioactivity of pedestrians passing by, determine whether they are carrying radioactive materials and identify nuclides, and issue sound and light alarm information.

 

The system is small in size, light in weight, easy to move, and its appearance design is easy to integrate into the surrounding environment. It has strong measurement concealment, is easy to deploy quickly, and can be put into use quickly. It is suitable for large-scale conferences, activities and other places to perform various temporary and emergency detection tasks.

Product Overview

The CRMS2000-C column-type pedestrian radioactivity monitoring system is equipped with a high-sensitivity γ radiation detector and a neutron detector (optional) for automatic radioactivity monitoring. It can quickly, effectively and non-destructively check the radioactivity of pedestrians passing by, determine whether they are carrying radioactive materials and identify nuclides, and issue sound and light alarm information.

 

The system is small in size, light in weight, easy to move, and its appearance design is easy to integrate into the surrounding environment. It has strong measurement concealment, is easy to deploy quickly, and can be put into use quickly. It is suitable for large-scale conferences, activities and other places to perform various temporary and emergency detection tasks.

Features

① Fast alarm response: Adopting fluctuation analysis and real-time background subtraction technology, high detection sensitivity and fast alarm response;

② Efficient disassembly and assembly: No tools are required for disassembly and assembly, and it can be quickly deployed and evacuated;

③ High traffic efficiency: The measurement is highly concealed, and personnel can pass quickly without stopping;

④ Efficient nuclide identification: Adopting characteristic peak fitting and overlapping peak stripping technology, it can quickly identify the type of nuclide;

⑤ Automatic background elimination: Natural nuclides automatically stabilize the spectrum, eliminate the influence of environmental changes, and ensure measurement accuracy;

⑥ Multiple nuclide identification: It can identify a variety of common γ-radioactive nuclides and classify them according to special nuclear materials, medical radionuclides, natural radionuclides, and industrial radionuclides.

Features

① Fast alarm response: Adopting fluctuation analysis and real-time background subtraction technology, high detection sensitivity and fast alarm response;

② Efficient disassembly and assembly: No tools are required for disassembly and assembly, and it can be quickly deployed and evacuated;

③ High traffic efficiency: The measurement is highly concealed, and personnel can pass quickly without stopping;

④ Efficient nuclide identification: Adopting characteristic peak fitting and overlapping peak stripping technology, it can quickly identify the type of nuclide;

⑤ Automatic background elimination: Natural nuclides automatically stabilize the spectrum, eliminate the influence of environmental changes, and ensure measurement accuracy;

⑥ Multiple nuclide identification: It can identify a variety of common γ-radioactive nuclides and classify them according to special nuclear materials, medical radionuclides, natural radionuclides, and industrial radionuclides.

Technical Parameters

Product Model

CRMS2000-C

CRMS2000-C-RID

Detector Type

Plastic scintillator

NaI(Tl) crystal

Number of detectors

3L×2

1L×2

Energy range

30keV~3MeV

30keV~3MeV

Nuclide identification function

/

Can identify multiple radioactive nuclides such as 226Ra, 232Th, 40K, 222Rn, 137Cs, 241Am, and special nuclear materials such as 235U and 238U. The nuclide library can be edited

System false alarm rate

≤0.015

≤0.015

Alarm response time

≤0.3s

≤0.3s

Power supply

AC220V

AC220V

Operating temperature

-30℃~55℃

-30℃~55℃

Operating humidity

0~95%RH

0~95%RH

Technical Parameters

Product Model

CRMS2000-C

CRMS2000-C-RID

Detector Type

Plastic scintillator

NaI(Tl) crystal

Number of detectors

3L×2

1L×2

Energy range

30keV~3MeV

30keV~3MeV

Nuclide identification function

/

Can identify multiple radioactive nuclides such as 226Ra, 232Th, 40K, 222Rn, 137Cs, 241Am, and special nuclear materials such as 235U and 238U. The nuclide library can be edited

System false alarm rate

≤0.015

≤0.015

Alarm response time

≤0.3s

≤0.3s

Power supply

AC220V

AC220V

Operating temperature

-30℃~55℃

-30℃~55℃

Operating humidity

0~95%RH

0~95%RH