English
  • English
  • Русский
  • Español
  • عربي

HA4700-M thyroid counter


Product Overview

The HA4700-M thyroid counter is primarily composed of a sodium iodide detector, energy spectrum analysis software, passive efficiency calibration software (optional), a computer, and a removable, adjustable stand. It uses energy spectrum analysis technology to measure the level of radioactive nuclides in the human thyroid gland and assesses the dose level in the human body based on the International Commission on Atomic Radiation (ICRP) standard metrological conversion method. It can also be used for lung radiation detection in emergency situations.

Product Overview

The HA4700-M thyroid counter is primarily composed of a sodium iodide detector, energy spectrum analysis software, passive efficiency calibration software (optional), a computer, and a removable, adjustable stand. It uses energy spectrum analysis technology to measure the level of radioactive nuclides in the human thyroid gland and assesses the dose level in the human body based on the International Commission on Atomic Radiation (ICRP) standard metrological conversion method. It can also be used for lung radiation detection in emergency situations.

Applications

This product is used in nuclear medicine to measure I-131 activity and dose assessment in the patient's thyroid gland. It can also be used for on-site measurement of radionuclide activity in human organs during nuclear emergencies, at nuclear power plants, at reprocessing plants, and at special nuclear material processing sites, serving as an emergency response device for disease prevention and control centers.

 

Features

① Equipped with a movable, height- and angle-adjustable stand, it facilitates measurement positioning.

② The system offers a simple workflow and a fully Chinese interface for rapid thyroid and lung activity measurements.

③ Features include automatic spectrum stabilization, energy scaling, peak detection, repeated peak analysis, activity calculation, and uncertainty analysis.

④ Gain and high voltage adjustments are available, along with real-time display of live/live time and discrimination thresholds.

⑤ A built-in library of commonly used radionuclides allows users to add new nuclides.

⑥ Directly input diagnostic conclusions, automatically output measurement and analysis reports, and support external printing.

Applications

This product is used in nuclear medicine to measure I-131 activity and dose assessment in the patient's thyroid gland. It can also be used for on-site measurement of radionuclide activity in human organs during nuclear emergencies, at nuclear power plants, at reprocessing plants, and at special nuclear material processing sites, serving as an emergency response device for disease prevention and control centers.

 

Features

① Equipped with a movable, height- and angle-adjustable stand, it facilitates measurement positioning.

② The system offers a simple workflow and a fully Chinese interface for rapid thyroid and lung activity measurements.

③ Features include automatic spectrum stabilization, energy scaling, peak detection, repeated peak analysis, activity calculation, and uncertainty analysis.

④ Gain and high voltage adjustments are available, along with real-time display of live/live time and discrimination thresholds.

⑤ A built-in library of commonly used radionuclides allows users to add new nuclides.

⑥ Directly input diagnostic conclusions, automatically output measurement and analysis reports, and support external printing.

Technical Parameters

Product Model

HA4700-M

Detector type

NaI crystal

Detector size

φ50mm*50mm

Communication methods

USB

Energy range

50KeV~3MeV

Energy resolution

≤7.5%

Multi-channel

1024

Detection lower limit (180s)

131I≤80Bq;133I≤100Bq

Measurement speed

≤3min

Operating temperature

-10~50℃

relative humidity

≤90%(35℃)

 

Technical Parameters

Product Model

HA4700-M

Detector type

NaI crystal

Detector size

φ50mm*50mm

Communication methods

USB

Energy range

50KeV~3MeV

Energy resolution

≤7.5%

Multi-channel

1024

Detection lower limit (180s)

131I≤80Bq;133I≤100Bq

Measurement speed

≤3min

Operating temperature

-10~50℃

relative humidity

≤90%(35℃)

 