Whole-body pollution monitoring system


Product Overview

The CRMS2000-G whole body contamination monitoring system is equipped with a high-sensitivity γ radiation detector, which is mainly installed at the entrance and exit of the radioactive workplace to monitor the whole body γ radioactive contamination of radioactive workers.

 

The system is equipped with multiple positioning sensors to standardize the position of the measured personnel, and correct the position of the personnel through the display screen and voice, and prompt the measurement results; the exit of the monitor is equipped with a gate rod, which is linked to the monitoring results to prohibit the passage of personnel with excessive radioactivity. The system can be connected to the superior management system to build a remote real-time monitoring information system platform.

Product Overview

The CRMS2000-G whole body contamination monitoring system is equipped with a high-sensitivity γ radiation detector, which is mainly installed at the entrance and exit of the radioactive workplace to monitor the whole body γ radioactive contamination of radioactive workers.

 

The system is equipped with multiple positioning sensors to standardize the position of the measured personnel, and correct the position of the personnel through the display screen and voice, and prompt the measurement results; the exit of the monitor is equipped with a gate rod, which is linked to the monitoring results to prohibit the passage of personnel with excessive radioactivity. The system can be connected to the superior management system to build a remote real-time monitoring information system platform.

Features

① Used in radioactive nuclear medicine production workshops and radioactive source safety supervision sites;

② Use large-volume plastic scintillator detectors with high detection sensitivity;

③ Use fluctuation analysis and real-time background subtraction technology to effectively reduce the system false alarm rate;

④ Use diffuse reflective infrared sensors plus multiple groups of infrared sensors to detect personnel positions, which can accurately determine the personnel's position and give voice prompts.

Features

① Used in radioactive nuclear medicine production workshops and radioactive source safety supervision sites;

② Use large-volume plastic scintillator detectors with high detection sensitivity;

③ Use fluctuation analysis and real-time background subtraction technology to effectively reduce the system false alarm rate;

④ Use diffuse reflective infrared sensors plus multiple groups of infrared sensors to detect personnel positions, which can accurately determine the personnel's position and give voice prompts.

Technical Parameters

Product Model

CRMS2000-G

Detector Type

Plastic scintillator

Detector size

15L×2

Static detection efficiency

241Am≥180s-1MBq-1, 137Cs≥800s-1MBq-1, 60Co≥1500s-1MBq-1

Energy range

30keV~3MeV

Detection height

0m~2m

Detection width

0m~0.7m

System false alarm rate

≤0.1%

Power supply

AC220V

Technical Parameters

Product Model

CRMS2000-G

Detector Type

Plastic scintillator

Detector size

15L×2

Static detection efficiency

241Am≥180s-1MBq-1, 137Cs≥800s-1MBq-1, 60Co≥1500s-1MBq-1

Energy range

30keV~3MeV

Detection height

0m~2m

Detection width

0m~0.7m

System false alarm rate

≤0.1%

Power supply

AC220V