Product Overview
The RC4000 (RC4000-T) hand and foot surface contamination monitor integrates a large-area dual-scintillator detector and is used to monitor the α and β surface radioactive contamination levels of the hands, feet and clothing of workers leaving the radioactive work area. The system is equipped with multiple positioning sensors to standardize the position of the measured personnel, and corrects the personnel's position and prompts the measurement results through a 10-inch display and voice prompts.
Product Overview
The RC4000 (RC4000-T) hand and foot surface contamination monitor integrates a large-area dual-scintillator detector and is used to monitor the α and β surface radioactive contamination levels of the hands, feet and clothing of workers leaving the radioactive work area. The system is equipped with multiple positioning sensors to standardize the position of the measured personnel, and corrects the personnel's position and prompts the measurement results through a 10-inch display and voice prompts.
Features
① Monitoring of α and β surface contamination on hands and feet of personnel;
② Multiple measurement modes for α and β, and multi-channel display of monitoring data;
③ Monitoring of α and β surface contamination on personnel clothing;
④ Real-time background monitoring, automatic update, and automatic deduction;
⑤ Dynamic display of monitoring data, and local storage of measurement results;
⑥ Monitoring data supports remote reporting and data export;
⑦ Polished stainless steel detection surface, not easy to be contaminated and easy to clean.
Features
① Monitoring of α and β surface contamination on hands and feet of personnel;
② Multiple measurement modes for α and β, and multi-channel display of monitoring data;
③ Monitoring of α and β surface contamination on personnel clothing;
④ Real-time background monitoring, automatic update, and automatic deduction;
⑤ Dynamic display of monitoring data, and local storage of measurement results;
⑥ Monitoring data supports remote reporting and data export;
⑦ Polished stainless steel detection surface, not easy to be contaminated and easy to clean.
Technical Parameters
Product Model |
RC4000 |
RC4000-T |
Detector Type |
Plastic scintillator + ZnS(Ag) |
Plastic scintillator + ZnS(Ag) |
Measurement ray type |
α+β/α/β |
α+β/α/β |
Hand detection area |
(200×120)mm2×4 |
(200×120)mm2×2 |
Foot detection area |
(350×150)mm2×2 |
(350×150)mm2×2 |
Detection lower limit (environmental background: 0.1μSv/h, measurement time 10s) |
α<0.04 Bq/cm2(239Pu) β<0.40 Bq/cm2(90Sr-90Y) |
α<0.04 Bq/cm2(239Pu) β<0.40 Bq/cm2(90Sr-90Y) |
Technical Parameters
Product Model |
RC4000 |
RC4000-T |
Detector Type |
Plastic scintillator + ZnS(Ag) |
Plastic scintillator + ZnS(Ag) |
Measurement ray type |
α+β/α/β |
α+β/α/β |
Hand detection area |
(200×120)mm2×4 |
(200×120)mm2×2 |
Foot detection area |
(350×150)mm2×2 |
(350×150)mm2×2 |
Detection lower limit (environmental background: 0.1μSv/h, measurement time 10s) |
α<0.04 Bq/cm2(239Pu) β<0.40 Bq/cm2(90Sr-90Y) |
α<0.04 Bq/cm2(239Pu) β<0.40 Bq/cm2(90Sr-90Y) |